Heart failure & cardiomyopathiesDiagnostic or prognostic study

Invasive haemodynamic validation of an artificial intelligence echocardiographic tool for detecting heart failure with preserved ejection fraction

ESC Heart FailPublished

  • external validation
  • retrospective
  • real-world referral cohort

Authors' conclusion

This AI model demonstrated high specificity and positive predictive value (PPV) for detecting HFpEF, reliably identifying patients with more advanced haemodynamic abnormalities. Its performance remained robust across variable intervals between transthoracic echocardiography (TTE) and right heart catheterization (RHC), and in patients with indeterminate clinical scores. Due to limited sensitivity, the tool is best utilized to enrich identification of patients with clearly abnormal haemodynamics rather than to exclude HFpEF, particularly in early or borderline cases. While broader use as a screening tool is promising, prospective validation studies are necessary to confirm its utility in general populations.

Study context

Population
Patients with unexplained dyspnoea who underwent transthoracic echocardiography (TTE) and right heart catheterization (RHC)including 28 with both rest and exercise haemodynamics
Participants
47 patients
Comparison
Artificial intelligence (AI) tool for detecting heart failure with preserved ejection fraction (HFpEF) compared to invasive haemodynamic criteria
Outcome
Invasively defined HFpEF: PCWP ≥15 mmHg at rest or ≥25 mmHg with exercise

Performance

As reported in the abstract

Test or modelsensitivityspecificityPPVNPV
AI tool30%88%86%33%
Patients with exercise RHC (n = 28) meeting haemodynamic HFpEF criteria
71%

Further findings

OutcomeAI toolInvasive haemodynamic criteriaEstimateP value
PCWP/CO slope >2 mmHg/L/min (secondary analysis, n = 25)
specificity100%Not reported in the abstract
PPV100%Not reported in the abstract
sensitivity27%Not reported in the abstract
NPV16%Not reported in the abstract
Haemodynamics in AI-positive vs AI-negative patients — AI-positive · significantly higher in AI-positiveresting PCWP 20 vs 15 mmHgP = 0.029
Haemodynamics in AI-positive vs AI-negative patients — AI-positive · significantly higher in AI-positivemean PA pressure 29 vs 24 mmHgP = 0.02
Haemodynamics in AI-positive vs AI-negative patients — AI-positive · significantly higher in AI-positivePVR 2.1 vs 1.3 WUP = 0.002

Indeterminate H2FPEF scores (n = 25)

AI correctly identified, of those with invasively confirmed HFpEF
80%

Performance by TTE-RHC interval

Model performance was consistent across TTE-RHC intervals <365 and <90 days

Original publication

Invasive haemodynamic validation of an artificial intelligence echocardiographic tool for detecting heart failure with preserved ejection fraction. ESC Heart Fail. Published 7 April 2026. doi:10.1093/eschf/xvag052

Summarised from the published abstract; every number is checked against it