Isometric exercise training in patients with heart failure with preserved ejection fraction: a randomized controlled study

Eur J Prev CardiolPublished Randomised controlled trial

Authors' conclusion

Isometric exercise training is a feasible and safe therapeutic intervention for patients with HFpEF, with cardiovascular and quality of life improvements.

Study context

Population
Medically optimized patients with heart failure with preserved ejection fraction (HFpEF)33 (87%) completed
Participants
19 vs 19
Comparison
Isometric exercise training vs usual care
  • Isometric exercise training (IET)n = 19
  • Usual caren = 19reference
Primary endpoint
Feasibility of an IET programme (exploratory safety and efficacy outcomes)

Primary result

As reported in the abstract

after 4-week intervention
IET vs Usual care · resting SBP
difference −8.52 ± 2.7 mmHg; P = 0.003
IET vs Usual care · resting mean BP
difference −4.94 ± 2 mmHg; P = 0.018
IET vs Usual care · resting DBP
difference −4.62 ± 1.8 mmHg; P = 0.016
Between IET and Usual care · total peripheral resistance (reduction)
difference 270.4 ± 75.4 dyne s cm-5; P = 0.001

Further findings

Cardiac function and KCCQ physical limitation, following IET

OutcomeEstimateP value
Between IET and Usual care · GLS improvementdifference 2.18 ± 0.7 %P = 0.005
Between IET and Usual care · LA reservoir strain improvementdifference 4.59 ± 1.7 %P = 0.012
IET vs Usual care · LA stiffness indexdifference −0.2 ± 0.06
Between IET and Usual care · KCCQ physical limitation subscaledifference 10.27 ± 4.56P = 0.032

Original publication

Isometric exercise training in patients with heart failure with preserved ejection fraction: a randomized controlled study. Eur J Prev Cardiol. Published 28 August 2025. doi:10.1093/eurjpc/zwaf541

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.