Arrhythmias & electrophysiologyCohort study

Lead Extraction and Mortality Among Patients With Cardiac Implanted Electronic Device Infection

JAMA CardiolPublished

  • Retrospective cohort study
  • nationwide
  • time-varying multivariable Cox regression
  • Mean (SD) follow-up 4.6 (2.9) years after implantation

Authors' conclusion

In this study, a minority of patients with CIED infection underwent extraction. Extraction was associated with a lower risk of death compared with no extraction.

Study context

Population
Fee-for-service Medicare Part D beneficiaries with de novo cardiovascular implantable electronic device (CIED) implantation, 2006–2019; CIED infection >1 year after implantation11,304 with CIED infection
Participants
1,065,549 beneficiaries
Exposure
Lead extraction vs no extraction in CIED infection
  • Any extractionn = 2,102
  • Extraction within 6 daysn = 1,511
  • Extraction days 7–30n = 591
  • No extractionn = 9,202reference
Outcome
Device infection, device extraction and all-cause mortality

Main finding

As reported in the abstract

All-cause mortality
Each group vs no extractionAdjusted hazard ratio (95% CI)P value
Any extraction
0.82(0.74–0.90)
P < 0.001
Extraction within 6 days
0.69(0.61–0.78)
P < 0.001
CIED infection
11 304 (1.1%)
Extraction within 30 days of diagnosis
2102 (18.6%)
1-year survival after infection
68.3%

Observational data: associations, not effects.

Further findings

Time from implantation to infection

Mean (SD) years after implantation
3.7 (2.4)

Original publication

Lead Extraction and Mortality Among Patients With Cardiac Implanted Electronic Device Infection. JAMA Cardiol. Published 1 December 2023. doi:10.1001/jamacardio.2023.3379

Summarised from the published abstract; every number is checked against it