Arrhythmias & electrophysiologyCohort study

Leadless pacemaker, right ventricular pacing burden, and heart failure

Heart RhythmPublished

  • registry-based observational study

Authors' conclusion

Baseline %RVP thresholds of 20% and 40% may help identify patients with LPs who are at an increased risk of HF. However, the HF hazard increased progressively with an increasing %RVP. Given the lack of established upgrade pathways for current LP systems, careful patient selection and follow-up may be particularly important for patients expected to have a high pacing burden.

Study context

Population
Patients who underwent leadless pacemaker implantation from 2015 to 2025, without a prior heart failure (HF) diagnosispatients with single-chamber leadless pacemakers (LPs)
Participants
3,167 patients
Exposure
Patients with higher baseline %RVP at 20% and 40% cutoffs compared with those with lower %RVP
Outcome
First recorded HF diagnosis
Follow-up
Over 2.4 years

Main finding

As reported in the abstract

patients had the primary outcome

577 (18%)

Observational data: associations, not effects.

Further findings

HF risk by baseline %RVP at 20% and 40% cutoffs

Higher baseline %RVP had increased risks of HF compared with lower %RVP
P < 0.05

HF hazard with time-varying %RVP

per 10% increase, hazard ratio
1.035 [1.013-1.059]
  • multivariable Cox model

Baseline characteristics and pacing burden

mean age
76 ± 13 years
women
45%
median baseline %RVP
71% (8%-98%)
median absolute %RVP difference over 2.4 years
5.5% (0.7%-21.6%)

Original publication

Leadless pacemaker, right ventricular pacing burden, and heart failure. Heart Rhythm. Published 4 September 2026. doi:10.1016/j.hrthm.2026.09.001

Summarised from the published abstract; every number is checked against it