Arrhythmias & electrophysiologyCohort study
Left atrial ablation using the dual-energy, lattice-tip catheter in the SAFE-Ablation Registry: How to avoid procedure-related stroke?
- single-center retrospective registry
- consecutive patients
- 2 sequential timeframes
Authors' conclusion
During left-sided RFA with the lattice-tip catheter, use of the default settings is associated with procedure-related stroke. Ablation is safest when employing PFA-only or RFA using attenuated energy settings.
Study context
- Population
- Consecutive patients undergoing left atrial ablation using the dual-energy, lattice-tip catheter (de novo and redo-ablation)patients undergoing catheter ablation · Period-1 294 · Period-2 213
- Participants
- 507 patients
- Exposure
- Pulsed field ablation (PFA)+RFALA using default radiofrequency (RF) settings vs PFA-only or PFA+RFALA-Attenuated
- PFA+RFALAn = 164
- PFA-onlyn = 130
- PFA-onlyn = 136
- PFA+RFALA-Attenuatedn = 77
Main finding
As reported in the abstract
Procedure-related stroke, Period-1
P = 0.073
- Patients with procedure-related stroke during Period-1, all when using PFA+RFALA
- 4 patients (1.4%)
Observational data: associations, not effects.
Further findings
Procedure-related stroke, combined cohorts
P = 0.004
- Procedure-related stroke, combined cohorts: stroke significantly more likely with PFA+RFALA using default RF settings
Procedure-related stroke, Period-2
- 213 procedures using PFA-only or PFA+RFALA-Attenuated, all without stroke
Redo-ablation
- Redo-ablation
- 54.4%
Original publication
Left atrial ablation using the dual-energy, lattice-tip catheter in the SAFE-Ablation Registry: How to avoid procedure-related stroke? Heart Rhythm. Published 11 April 2026. doi:10.1016/j.hrthm.2026.04.001
Summarised from the published abstract; every number is checked against it