Cardio-oncology & otherCohort study

Long-term incidence of infective endocarditis according to the type of cardiac implantable electronic device: a nationwide comparison with moderate- and high-risk patient groups

EuropacePublished

  • Nationwide registry-based cohort study
  • Danish nationwide registries

Authors' conclusion

In this nationwide cohort, IE risk differed across CIED types, highest in CRT-D and lowest in pacemaker recipients. All CIED types were associated with higher risk than moderate-risk patients but lower risk than high-risk patients, supporting ESC classification.

Study context

Population
Patients with first-time cardiac implantable electronic device (CIED) implantation and reference populations at moderate and high infective endocarditis (IE) risk, Denmark, 2000–2022; CIED group excluded prior IE or left-sided prosthetic valve84,171 CIED recipients
Exposure
CIED types vs moderate- and high-risk IE reference groups
  • Moderate-riskn = 127,966reference
  • High-riskn = 23,505
Outcome
Incident IE
Follow-up
Within 10 years

Main finding

As reported in the abstract

10-year cumulative incidence of IE · 10 years

Observational data: associations, not effects.

Original publication

Long-term incidence of infective endocarditis according to the type of cardiac implantable electronic device: a nationwide comparison with moderate- and high-risk patient groups. Europace. Published 28 August 2026. doi:10.1093/europace/euag232

Summarised from the published abstract; every number is checked against it