Arrhythmias & electrophysiologyDiagnostic or prognostic study

Long-term reliability of the phospholamban (PLN) p.(Arg14del) risk model in predicting major ventricular arrhythmia: a landmark study

EuropacePublished

  • Prognostic model validation study
  • landmark analysis

Authors' conclusion

The PLN p.(Arg14del) risk model has sustained good model performance up to 3 years follow-up in PLN p.(Arg14del)-positive subjects with no history of major VA.

Study context

Population
PLN p.(Arg14del)-positive individuals with no prior major ventricular arrhythmia (VA) at the 3-year landmark
Participants
268 participants
Outcome
Diagnostic performance of the PLN p.(Arg14del) risk model for major VA (sustained VA, appropriate implantable cardioverter defibrillator (ICD) intervention or (aborted) SCD)
Follow-up
3-year follow-up

Performance

As reported in the abstract

Risk model performance in the 3-year landmark cohort

C-statistic

0.83 (95% CI 0.79-0.87)

Calibration slope

0.97

Further findings

Major VA after the 3-year landmark · mean follow-up 4.0 years (± 3.5 years)

Subjects with major VA
28 (10%)
Annual event rate
2.6% (95% CI 1.6-3.6)

Original publication

Long-term reliability of the phospholamban (PLN) p.(Arg14del) risk model in predicting major ventricular arrhythmia: a landmark study. Europace. Published 1 April 2024. doi:10.1093/europace/euae069

Summarised from the published abstract; every number is checked against it