Arrhythmias & electrophysiology

Mechanical resynchronization in left bundle branch block achieved by conduction system pacing: A strain-based analysis

Heart RhythmPublished

  • multicenter study

Authors' conclusion

LBBAP provides substantial mechanical resynchronization with immediate and progressive improvements in septal mechanics. Resynchronization was not significantly different between LBBP and LVSP, but was attenuated in DSP, where residual dyssynchrony was associated with lower LVEF 1-year after implantation.

Study context

Population
Patients undergoing left bundle branch area pacing (LBBAP) with left bundle branch block (LBBB) or need for upgrade from right ventricular pacing, across the full range of left ventricular ejection fraction (LVEF)
Comparison
Resynchronization between left bundle branch pacing (LBBP), LV septal pacing (LVSP) and deep septal pacing (DSP)

Main finding

As reported in the abstract

Type of capture during follow-up · follow-up

Further findings

Septal strain patterns · after implantation

Septal strain patterns improved immediately and progressively after implantation
P = 0.01

Global longitudinal strain (GLS) · baseline to follow-up

GLS at baseline
−12 ± 6%
GLS at follow-up
−15 ± 6%
P
P < 0.001

Resynchronization by capture type · 1 year

Inferior in DSP, lower Δ mid-septal peak septal strain
P = 0.004
Inferior in DSP, lower ΔLVEF
P = 0.03
Not significantly different between LBBP and LVSP

Reverse remodeling (regression analysis)

Both LBBB-stages and type of LBBAP-capture were associated with reverse remodeling following LBBAP

Original publication

Mechanical resynchronization in left bundle branch block achieved by conduction system pacing: A strain-based analysis. Heart Rhythm. Published 5 May 2026. doi:10.1016/j.hrthm.2026.04.055

Summarised from the published abstract; every number is checked against it