Authors' conclusion

This meta-analysis found no association between paclitaxel-coated device exposure and risk of death, providing reassurance to patients, physicians, and regulators on the safety of paclitaxel-coated devices.

Study context

Population
Patients with femoropopliteal occlusive disease undergoing interventional procedures
Participants
2,666 patients · 10 RCTs
Comparison
Paclitaxel-coated vs control devices
Outcome
Death (all-cause mortality), ITT analysis
Follow-up
Median 4.9 years

Pooled result

Death

Hazard ratio

1.14

95% CI 0.93–1.40

Paclitaxel-coated vs Control
HR 1.14 (95% CI 0.93–1.40)

As reported in the abstract

Further pooled results

OutcomeHR
Death, as-treated and crossover analyses — Paclitaxel-coated vs Control · as-treated1.13 (95% CI 0.92–1.39)
Death, as-treated and crossover analyses — Paclitaxel-coated vs Control · late crossovers censored1.07 (CI 0.87–1.31)
Death, as-treated and crossover analyses — Paclitaxel-coated vs Control · crossovers analysed from date of paclitaxel exposure1.04 (CI 0.84–1.28)

Paclitaxel dose and mortality

No significant effect of paclitaxel dose on mortality risk