Heart failure & cardiomyopathiesCohort study

Mortality reduction with implanted defibrillator for primary prevention of sudden death after Myocardial Infarction: temporal trends in the PROFID study

Eur Heart JPublished

  • Pooled cohort study (individual participant data)
  • propensity-score overlap weighting
  • prespecified time periods

Authors' conclusion

In this analysis including a large cohort of post-myocardial infarction patients with reduced LVEF, the estimated mortality reduction associated with primary prevention ICD implantation progressively decreased over time.

Study context

Population
Post-MI patients with left ventricular ejection fraction (LVEF) ≤35%, PROFID pooled cohort, inclusion 1995–202012,097 deaths
Participants
32,214 patients
Exposure
Primary prevention implantable cardioverter-defibrillator (ICD) vs no ICD, by time period
  • ICDn = 7,477
  • Non-ICDn = 24,737reference
Outcome
All-cause mortality
Follow-up
Mean 43.7 months

Main finding

As reported in the abstract

All-cause mortality by inclusion period
ICD vs Non-ICDHazard ratio (95% CI)P value
1995-2004
0.54(0.47–0.62)
P < 0.001
2005-2014
0.67(0.62–0.72)
P < 0.001
2015-2020
0.89(0.73–1.07)
P = 0.221

Observational data: associations, not effects.

Original publication

Mortality reduction with implanted defibrillator for primary prevention of sudden death after Myocardial Infarction: temporal trends in the PROFID study. Eur Heart J. Published 28 August 2026. doi:10.1093/eurheartj/ehag706

Summarised from the published abstract; every number is checked against it