Motion-Informed Neural Network Towards Diastolic Mechanics in Takotsubo Syndrome
Authors' conclusion
MiNN-Echo in echocardiograms elucidates unique myocardial relaxation kinematics to characterize TTS-associated diastolic mechanics.
Study context
- Population
- Patients with Takotsubo syndrome (TTS) or anterior myocardial infarctionpatients whose echocardiograms were used, 68 expert echocardiographic readers performed human interpretation · 596 (TTS) · 546 (anterior myocardial infarction)
- Participants
- 1,142 patients
- Index test or model
- MiNN-Echo vs human readers in differentiating TTS from acute myocardial infarction
- Human readersn = 68
- Target condition
- TTS (differentiated from acute myocardial infarction)
Methodological detailsmulti-vendor echocardiograms, multi-institutional cohort, trained and validated
- Multi-vendor echocardiograms
- Multi-institutional cohort
- Trained and validated
Performance
As reported in the abstract
TTS (differentiated from acute myocardial infarction)
| Test or model | AUC |
|---|---|
| MiNN-Echo | 0.77 |
| Human readers | 0.69 |
AUC
MiNN-Echo0.77
Human readers0.69
Further findings
Isovolumic relaxation time
% of diastolic time TTS 28% · Acute myocardial infarction 19%
Passive ventricular filling (before atrial contraction) time
% of diastolic time TTS 44% · Acute myocardial infarction 54%
Median
| Outcome | TTS | Acute myocardial infarction |
|---|---|---|
| Pixel-wise myocardial displacement, isovolumic relaxation phase | 0.35 (IQR 0.26–0.47) | 0.38 (IQR 0.28–0.51) |
| Pixel-wise myocardial displacement, passive ventricular filling phase | 0.45 (IQR 0.33–0.58) | 0.50 (IQR 0.38–0.68) |
| Pixel-wise myocardial displacement, active ventricular filling phase | 0.43 (IQR 0.32–0.56) | 0.48 (IQR 0.35–0.63) |
| Rotation angles (away from the horizontal A-V plane), passive ventricular filling phase | −70.19 (IQR −89.62 to −41.33) | −60.34 (IQR −87.07 to −30.84) |
- Isovolumic relaxation time: increased in TTS; P <0.001 (ms); P <0.001 (% of diastolic time)
- Passive ventricular filling (before atrial contraction) time: decreased in TTS; P <0.001 (ms); P <0.001 (% of diastolic time)
- Pixel-wise myocardial displacement, isovolumic relaxation phase: lower in TTS; P =0.006
- Pixel-wise myocardial displacement, passive ventricular filling phase: lower in TTS; P <0.001
- Pixel-wise myocardial displacement, active ventricular filling phase: lower in TTS; P =0.001
- Rotation angles (away from the horizontal A-V plane), passive ventricular filling phase: altered in TTS; P =0.020
Contribution of diastolic myocardial motion features to the differential diagnosis
- Diastolic motion features contributed more than those during systole
- ≈71%
Original publication
Motion-Informed Neural Network Towards Diastolic Mechanics in Takotsubo Syndrome. Circ Cardiovasc Imaging. Published 11 November 2026. doi:10. 1161/ circimaging. 126. 020258
Composed by AI from the published abstract and checked against it. How Briefs are made →