Myocardial Flow Assessment After Heart Transplantation Using Dynamic Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography With 201 Tl and 99m Tc Tracers and Validated by 13 N-NH 3 Positron Emission Tomography

Circ Cardiovasc ImagingPublished Diagnostic accuracy study

Authors' conclusion

This small study suggests that CZT SPECT using 201Tl and 99mTc tracers showed comparable MBF and MFR, and the results correlated well with those of 13 N-NH3 PET.

Study context

Population
Patients with prior heart transplantation undergoing cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) and 13 N-NH3 positron emission tomography (PET) dynamic scans; Cardiac allograft vasculopathy (CAV) assessment
Participants
38 patients
Comparison
Dynamic CZT SPECT with 201Tl or 99mTc tracers vs 13 N-NH3 PET for myocardial blood flow (MBF) and myocardial flow reserve (MFR) quantification
  • 99mTcn = 19
Outcome
Diagnostic performance for CAV (MBF and MFR quantification), validated by 13 N-NH3 PET

Performance

As reported in the abstract

Detection of PET MFR <2.0
StrategyAUC
201Tl0.92 [0.71-0.99]
99mTc0.87 [0.64-0.97]

AUC

201Tl0.92 [0.71-0.99]
99mTc0.87 [0.64-0.97]

Further findings

Outcome201Tl99mTcPETP value
Correlation of CZT SPECT vs PET for stress MBFcorrelation coefficient 0.95correlation coefficient 0.80Not reported in the abstractP = 0.03PET: not reported in the abstract
Detection of angiographically defined moderate-to-severe CAV
AUCNot reported in the abstractNot reported in the abstract0.86 [0.64-0.97]201Tl, 99mTc: not reported in the abstract
  • Detection of angiographically defined moderate-to-severe CAV: CZT SPECT AUC 0.90 [0.70-0.99]
  • Detection of angiographically defined moderate-to-severe CAV: patients with angiography within 1 year of second scan

Correlation of CZT SPECT vs PET for stress MBF

No significant difference between cohorts in correlation coefficients for other MBF and MFR values

Detection of angiographically defined moderate-to-severe CAV

CZT SPECT comparable to 13 N-NH3 PET

Original publication

Myocardial Flow Assessment After Heart Transplantation Using Dynamic Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography With 201 Tl and 99m Tc Tracers and Validated by 13 N-NH 3 Positron Emission Tomography. Circ Cardiovasc Imaging. Published 14 June 2023. doi:10.1161/circimaging.122.015034

Summarised from the published abstract; every number is checked against it