Coronary disease & ACS

Myocardial Perfusion Imaging With Positron Emission Tomography (PET): A Head-to-Head Comparison of 82 Rubidium Versus 15 O-water Tracers Using Invasive Coronary Measurements as Reference

Circ Cardiovasc ImagingPublished head-to-head comparison

Authors' conclusion

For detection of obstructive CAD by PET myocardial perfusion imaging, 82 Rb versus 15 O-water have similar diagnostic performance.

Study context

Population
Consecutive patients referred for computed tomography angiography (CTA) with symptoms suggestive of obstructive coronary artery disease (CAD); those with suspected stenosis on CTA referred for 82 Rb-PET, 15 O-water-PET and invasive coronary angiography (ICA)consecutive patients referred for CTA, 196/270 (73%) patients with suspected stenosis on CTA completed 82 Rb-PET, 15 O-water-PET, and ICA
Participants
1,000 patients
Comparison
82 Rb-PET vs 15 O-water-PET
Outcome
Correlation of myocardial blood flow, 82 Rb-PET vs 15 O-water-PET
Methodological detailsconsecutive patients, invasive coronary measurements as reference
  • Consecutive patients
  • Invasive coronary measurements as reference

Main finding

As reported in the abstract

At rest (correlated strongly)

ρ, 0.62-0.69

During hyperemia (only moderately)

ρ, 0.41-0.59

Further findings

Outcome82 Rb-PET15 O-water-PETP value
Diagnostic accuracy vs ICA FFR ≤0.80, predefined cutoffs69% versus 71% · diagnostic accuracies similarP = 0.59
Sensitivity69% [58-78%]71% [60-80%]
Specificity85% [76-91%]77% [68-85%]
Diagnostic accuracy vs ICA FFR ≤0.80, predefined cutoffs85% versus 77% · diagnostic accuracies similarP = 0.12

Correlation of myocardial blood flow reserve by both PET tracers with ICA coronary flow reserve

Only weak correlations
ρ, 0.11-0.38

Hemodynamically obstructive CAD (ICA fractional flow reserve ≤0.80)

Patients with obstructive CAD
86/196 (44%)

Anatomically severe CAD (ICA diameter stenoses >70% as reference)

Patients with anatomically severe CAD
48/196 (24%)
82 Rb-PET and 15 O-water-PET sensitivities increased to
>85%

Original publication

Myocardial Perfusion Imaging With PET: A Head-to-Head Comparison of 82 Rubidium Versus 15 O-water Tracers Using Invasive Coronary Measurements as Reference. Circ Cardiovasc Imaging. Published 3 April 2025. doi:10.1161/circimaging.124.017479

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.