Valvular & structural heart diseaseCohort study

National Variability in Pacemaker Implantation Rate Following Transcatheter Aortic Valve Replacement (TAVR)

JACC Cardiovasc IntervPublished

  • Retrospective registry study
  • multicentre
  • hierarchical multivariable models

Authors' conclusion

Although PPM implantation rates have decreased over time, substantial site-level variation remains even after accounting for observed patient characteristics and site-level factors.

Study context

Population
TAVR procedures in the ACC/STS TVT Registry, 2016–2020TAVR procedures, 653 sites
Participants
184,452 procedures
Outcome
Hospital-level variation and temporal trends in PPM implantation (in-hospital and 30-day) after TAVR

Main finding

As reported in the abstract

PPM implantation after TAVR · 2016–2020
Overall permanent pacemaker (PPM) implantation rate
11.3%
Site range of PPM rates
0%-36.4%
Sites above 95th percentile CI (volume-adjusted)
34
Sites below 95th percentile CI (volume-adjusted)
28
Site variation after patient-level adjustment, median OR
1.39 (95% CI 1.35-1.43, P < 0.001)

Observational data: associations, not effects.

Original publication

National Variability in Pacemaker Implantation Rate Following TAVR. JACC Cardiovasc Interv. Published 12 February 2024. doi:10.1016/j.jcin.2023.12.005