Valvular & structural heart disease

National Variability in Pacemaker Implantation Rate Following Transcatheter Aortic Valve Replacement (TAVR): Insights From the STS/ACC TVT Registry

JACC Cardiovasc IntervPublished Retrospective registry study

Authors' conclusion

Although PPM implantation rates have decreased over time, substantial site-level variation remains even after accounting for observed patient characteristics and site-level factors.

Study context

Population
TAVR procedures in the ACC/STS TVT Registry, 2016–2020TAVR procedures, 653 sites
Participants
184,452 procedures
Outcome
Hospital-level variation and temporal trends in PPM implantation (in-hospital and 30-day) after TAVR
Methodological detailsmulticentre, hierarchical multivariable models
  • Multicentre
  • Hierarchical multivariable models

Main finding

As reported in the abstract

PPM implantation after TAVR · 2016–2020
Overall permanent pacemaker (PPM) implantation rate
11.3%
Site range of PPM rates
0%-36.4%
Sites above 95th percentile CI (volume-adjusted)
34
Sites below 95th percentile CI (volume-adjusted)
28
Site variation after patient-level adjustment, median OR
1.39 (95% CI 1.35-1.43, P < 0.001)

Original publication

National Variability in Pacemaker Implantation Rate Following TAVR: Insights From the STS/ACC TVT Registry. JACC Cardiovasc Interv. Published 12 February 2024. doi:10.1016/j.jcin.2023.12.005

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.