Arrhythmias & electrophysiology

Non-Invasive Median Nerve Stimulation with a Wearable Stimulator to Reduce Atrial Arrhythmia Recurrence after Atrial Fibrillation Ablation: The NEUROPULSE Pilot

Heart RhythmPublished randomized, double-blind, sham-controlled pilot study

Primary result · AF/atrial tachycardia/atrial flutter eventsResult — go to the resultRate ratio 17.93 95% CI 10.04–32.0

Authors' conclusion

Wearable MNS after AF ablation was associated with fewer recurrent atrial arrhythmia events. This pilot study warrants confirmation in an adequately powered trial.

Study context

Population
Patients undergoing atrial fibrillation (AF) ablation (largely pulsed field ablation)randomized 1:1, modified intention-to-treat population 59 · median nerve stimulation (MNS) (modified intention-to-treat) 31 · sham (modified intention-to-treat) 28
Participants
77 patients
Comparison
active MNS vs sham therapy after AF ablation
  • MNSn = 31
  • shamn = 28reference
Methodological details3-center
  • 3-center

Primary result

AF/atrial tachycardia/atrial flutter events · postblanking follow-up (months 2-6)

Rate ratio

17.93

95% CI 10.04–32.0

P < 0.0001

Events by treatment group

MNS

12

events

Sham

243

events

MNS vs sham
rate ratio 17.93 (95% CI 10.04–32.0); P < 0.0001

As reported in the abstract

Further findings

OutcomeMNSShamEstimateP value
AF/atrial tachycardia/atrial flutter events, excluding 1 high-burden sham outlier · postblanking follow-up (months 2-6) · more events with sham (12 vs 28)12 events28 eventsrate ratio 2.17 (95% CI 1.10–4.27)P = 0.025
AF/atrial tachycardia/atrial flutter recurrence; arrhythmia-free survival · 6 months · recurrence more frequent with sham (2 of 31 vs 5 of 28)6-month arrhythmia-free survival 90.0%6-month arrhythmia-free survival 80.8%hazard ratio 2.15 (95% CI 0.42–11.1)P = 0.36
  • AF/atrial tachycardia/atrial flutter events, excluding 1 high-burden sham outlier: after excluding 1 high-burden sham outlier

Premature atrial contraction counts and patient-reported outcomes

Did not differ

Baseline characteristics

Median age
67 years (interquartile range 56-74 years)
Female
39%
Paroxysmal AF
68%
Redo ablation
27%

Blinding

Blinding was maintained

Safety

MNS- or device-related serious adverse events

No MNS- or device-related serious adverse events occurred

Original publication

Non-Invasive Median Nerve Stimulation with a Wearable Stimulator to Reduce Atrial Arrhythmia Recurrence after Atrial Fibrillation Ablation: The NEUROPULSE Pilot. Heart Rhythm. Published 20 September 2026. doi:10.1016/j.hrthm.2026.09.013

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.