Cardio-oncology & other

Opportunistic Screening for Chagas Disease Using an Artificial Intelligence–Enabled ECG: Prospective Evaluation of Feasibility and Diagnostic Accuracy

CirculationPublished prospective study

Authors' conclusion

In this community-based study, an AI-ECG-EPI model integrated into a public telecardiology network enabled feasible opportunistic screening for ChD in primary care. It showed acceptable diagnostic accuracy, with higher discrimination than epidemiological questions and AI ECG-only models, and identified many previously undiagnosed patients in endemic regions, supporting its potential role in scalable screening strategies.

Study context

Population
Adults undergoing routine tele-ECGs in hyperendemic and endemic regions of Brazil, October 2023 to September 2024completed serology testing, 75,779 eligible ECGs, AI-ECG-EPI model available for 59,154 individuals, 7804 invited for serology · AI-ECG-EPI positive, completed testing 2,517 · AI-ECG-EPI negative, completed testing 992
Participants
3,509 adults
Exposure
AI-ECG-EPI model against serology (the reference standard); compared with both an epidemiological questions model and an artificial intelligence (AI) ECG-only model
Methodological detailsembedded in the Telehealth Network of Minas Gerais, Brazil, 107 municipalities in hyperendemic and endemic regions, index test-dependent sampling, Weighted analyses (inverse probability)
  • Embedded in the Telehealth Network of Minas Gerais, Brazil
  • 107 municipalities in hyperendemic and endemic regions
  • Index test-dependent sampling
  • Weighted analyses (inverse probability)

Main finding

As reported in the abstract

Screened positive by AI-ECG-EPI model

Screened positive

6812

11.5%

Observational data: associations, not effects.

Further findings

AUROC

OutcomeAI-ECG-EPI modelEpidemiological questions modelAI ECG-only model
Discrimination (area under the receiver operating characteristics curve)77.6%70.0%64.5%
Chagas disease (ChD) confirmed by serology — Weighted prevalence of ChD
12.2%
Diagnostic accuracy of the AI-ECG-EPI model
34.3% · Sensitivity · Specificity 91.6% · Harmonic mean of precision and recall score 0.52 · Diagnostic odds ratio 5.69
Discrimination (area under the receiver operating characteristics curve) — AI-ECG-EPI model showed higher discrimination than both comparators
P <0.001
  • ChD confirmed by serology: AI-ECG-EPI positive (tested) 36.8%
  • ChD confirmed by serology: AI-ECG-EPI negative (tested) 9.3%

Precision recall curves

Higher precision across most recall levels

Risk reclassification (exploratory)

Net reclassification improvement
0.503
  • Exploratory analysis

Performance by subgroup

Performance was higher in women and in individuals with Chagas cardiomyopathy

Original publication

Opportunistic Screening for Chagas Disease Using an Artificial Intelligence–Enabled ECG: Prospective Evaluation of Feasibility and Diagnostic Accuracy. Circulation. Published 8 September 2026. doi:10.1161/circulationaha.125.078949

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.