Arrhythmias & electrophysiologyCohort study

Outcomes of catheter ablation in high-risk patients with Brugada syndrome refusing an implantable cardioverter defibrillator implantation

EuropacePublished

  • Cohort study

Ventricular fibrillation (VF)-triggering PVCs ablated in 3 (16.7%), VF substrates in 15 (83.3%); epicardial ablation in 12 (66.7%)

Authors' conclusion

Catheter ablation is an effective alternative therapy for improving arrhythmic outcomes in patients with symptomatic BrS who decline ICD implantation.

Study context

Population
Patients with symptomatic Brugada syndrome
Participants
40 patients
Exposure
Catheter ablation (CA) vs implantable cardioverter defibrillator (ICD) implantation
Outcome
Composite of:
  • VF episodes
  • SCD
Follow-up
During

Main finding

As reported in the abstract

median follow-up 46.2 (17.5-73.7) months

CA

5.6

%

ICD

54.5%

Log-rank P = 0.012

Observational data: associations, not effects.

Further findings

OutcomeCAICDP value
Shanghai risk score (baseline) · comparable7.05 ± 0.806.71 ± 0.86P = 0.351

Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.

Original publication

Outcomes of catheter ablation in high-risk patients with Brugada syndrome refusing an implantable cardioverter defibrillator implantation. Europace. Published 27 October 2023. doi:10.1093/europace/euad318

Summarised from the published abstract; every number is checked against it