Valvular & structural heart diseaseCohort study

Outcomes of Entrapped Right Ventricular Pacing or Defibrillator Leads Following Transcatheter Tricuspid Valve Replacement

JACC Cardiovasc IntervPublished

  • Multicentre observational cohort study
  • 3 centres
  • consecutive patients

Authors' conclusion

Following TTVR, most with entrapped RV leads remain free of lead-related complications.

Study context

Population
Patients with a cardiac implantable electronic device (CIED) and transvenous right ventricular (RV) lead undergoing EVOQUE transcatheter tricuspid valve replacement (TTVR)of 146 EVOQUE TTVR
Participants
52 patients
Outcome
Nature and incidence of major lead-related complications after TTVR

Main finding

As reported in the abstract

Major procedure-related lead complications after TTVR

Patients with procedure-related lead complications

4

Intraprocedural RV lead dislodgement

1

ICD lead fractures 6 and 8 weeks post-TTVR

2

MRSA endocarditis 1 month post-TTVR

1

Observational data: associations, not effects.

Secondary outcomes

Other lead-related adverse events in complication-free patients with follow-up >30 days · 356 [196-965] days

No other lead-related adverse events among 46 complication-free patients

Paravalvular leak mild or less · 30 days post-TTVR

Paravalvular leak mild or less, patients of 48
47 (98%)

Lead parameter changes after entrapment (33 complication-free patients with ≥1 CIED interrogation >30 days) · 424 [182-1,006] days

Significant decrease in lead impedance and increase in capture threshold on final lead assessment
No additional patients required lead revision

Original publication

Outcomes of Entrapped Right Ventricular Pacing or Defibrillator Leads Following Transcatheter Tricuspid Valve Replacement. JACC Cardiovasc Interv. Published 28 July 2025. doi:10.1016/j.jcin.2025.05.042

Summarised from the published abstract; every number is checked against it