Valvular & structural heart diseaseCohort study

Outcomes of patients with large anatomies undergoing transcatheter tricuspid valve replacement with the LuX-Valve Plus system

EuroInterventionPublished

  • European TRINITY study cohort

Authors' conclusion

TTVR with the LuX-Valve Plus system to treat patients with severe or greater symptomatic TR and a large tricuspid annulus was associated with high intraprocedural and 30-day clinical success rates, significant TR reduction and functional improvement, and low permanent pacemaker implantation rates.

Study context

Population
Patients with severe or greater symptomatic tricuspid regurgitation (TR) and large tricuspid annuli undergoing transcatheter tricuspid valve replacement (TTVR) with the 55–70 mm LuX-Valve Plus system
Participants
114 enrolled patients
Outcome
Co-primary endpoints: intraprocedural and 30-day clinical success (Tricuspid Valve Academic Research Consortium criteria)
Follow-up
Intraprocedural and 30 days

Main finding

As reported in the abstract

Intraprocedural success

95.6%

Thirty-day clinical success

91.2%

Observational data: associations, not effects.

Further findings

Residual TR moderate or less

Patients with residual TR moderate or less
93.7%

Kansas City Cardiomyopathy Questionnaire score

Mean score improved from
57.3±20.7 points
Mean score improved to
71.0±23.5 points
  • p<0.001

New York Heart Association Class III-IV symptoms · 30 days

Baseline
57.1%
30 days
20.9%
  • p<0.001

Safety

OutcomeValues
Cardiac surgery within the first 24 hoursLuX-Valve Plus 1.8%
Pacemaker implantation · 30 daysLuX-Valve Plus 6.1%

Intraprocedural mortality or stroke

No cases of intraprocedural mortality or stroke

Original publication

Outcomes of patients with large anatomies undergoing transcatheter tricuspid valve replacement with the LuX-Valve Plus system. EuroIntervention. Published 17 August 2026. doi:10.4244/eij-d-26-00062

Summarised from the published abstract; every number is checked against it