Valvular & structural heart diseaseCohort study

Outcomes of Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Disease

CirculationPublished

  • Registry-based cohort study
  • multicentre
  • Medicare-linked

Authors' conclusion

Using current-generation devices, procedural, postprocedural, and 1-year outcomes were comparable following TAVR for bicuspid AV versus tricuspid AV disease.

Study context

Population
Patients undergoing transcatheter AV replacement (TAVR) in the STS/ACC TVT Registry, November 2011 through November 2018procedures at 593 sites
Participants
170,959 patients
Exposure
TAVR in bicuspid vs tricuspid aortic valve (AV) stenosis
  • Bicuspidn = 5,412
Outcome
Device success, procedural outcomes, post-TAVR valve performance and in-hospital outcomes (mortality, stroke, major bleeding); mortality and stroke to 1 year (Medicare, ≥65 years)

Main finding

As reported in the abstract

Device success, current-generation devices

P = 0.07

Observational data: associations, not effects.

Further findings

Residual moderate or severe aortic insufficiency, current-generation devices

P < 0.001

OutcomeHR (95% CI)P value
Mortality (adjusted), Medicare-linked cohort · 1 year0.88 (0.78–0.99)
Stroke (adjusted), Medicare-linked cohort · 1 year1.14 (0.94–1.39)
OutcomeEstimateP value
Bicuspid AV: current- vs older-generation devices — Current-generation vs Older-generation · device success 93.5 (older) versus 96.3 (current)P = 0.001
Bicuspid AV: current- vs older-generation devices — Current-generation vs Older-generation · 2+ aortic insufficiency 14.0% (older) versus 2.7% (current)P < 0.001

Original publication

Outcomes of Transcatheter Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Disease. Circulation. Published 26 February 2020. doi:10.1161/circulationaha.119.040333