Paclitaxel-Coated Balloon for the Treatment of Small Vessel In-Stent Restenosis: A Subgroup Analysis of the AGENT IDE Randomized Trial
Authors' conclusion
This prespecified subgroup analysis demonstrates that angioplasty with a PCB was associated with consistently reduced rates of 1-year TLF compared with an uncoated balloon in both SV and large vessel ISR patients.
Study context
- Population
- Patients with coronary in-stent restenosis (ISR), small vessel (RVD ≤2.75 mm) or large vessel (RVD >2.75 mm)597 with known vessel size
- Participants
- 600 patients
- Comparison
- Paclitaxel-coated balloon vs uncoated balloon angioplasty, by vessel size
- Primary endpoint
- Target lesion failure (TLF) (target lesion revascularization, cardiac death, target vessel-related MI)
- Follow-up
- 1 year
Methodological detailsprespecified subgroup analysis, 2:1 randomisation
- Prespecified subgroup analysis
- 2:1 randomisation
Primary result
As reported in the abstract
1-year TLF by vessel size
PCB vs Uncoated balloonHazard ratio (95% CI)
Small vessels: 17.7%vs 27.4%; 39% relative reduction
0.61(0.37–0.99)
Large vessels: 18.4%vs 30.5%; 43% reduction
0.57(0.34–0.96)
Key notes
- Interaction P = 0.88
Further findings
| Outcome | Small vessels | Large vessels | HR (95% CI) | P value | |
|---|---|---|---|---|---|
| 1-year TLF, smallvs large vessels (all patients) | 20.6% | 22.6% | 0.92 (0.65–1.31) | P = 0.65 | |
| 0.512Hazard ratio (log scale) |
Safety
- Definite or probable stent thrombosis — PCB
- 0 events
Original publication
Paclitaxel-Coated Balloon for the Treatment of Small Vessel In-Stent Restenosis: A Subgroup Analysis of the AGENT IDE Randomized Trial. JACC Cardiovasc Interv. Published 24 November 2025. doi:10. 1016/ j. jcin. 2025. 09. 032
Composed by AI from the published abstract and checked against it. How Briefs are made →