Coronary disease & ACS

Potential performance of a 0 h/1 h algorithm and a single cut-off measure of high-sensitivity troponin T in a diverse population: main results of the IN-HOPE study

Eur Heart J Acute Cardiovasc CarePublished Diagnostic accuracy study

Authors' conclusion

In this large multicentre study, a 0 h/1 h algorithm had the potential to classify as rule-in or rule-out in almost 80% of the patients. The rule-out protocol had high negative predictive value regardless of clinical risk scores. Categories of levels of hs-cTn T also showed good accuracy in discriminating risk of the patients with a very favourable prognosis for cardiovascular death in the group with value < 5 ng/L.

Study context

Population
Patients admitted to the emergency department (ED) with suspected symptoms of acute myocardial infarction (AMI), 16 sites in Brazil583 prospective, 4.914 retrospective
Participants
5.497 patients
Comparison
High-sensitivity cardiac troponin T (hs-cTnT) 0 h/1 h algorithm in patients managed by 0 h/3 h protocol
Outcome
Accuracy of 0 h/1 h algorithm overall and in groups with a higher probability of AMI
Methodological detailsmulticentre, prospective cohort with retrospective analysis, 16 sites in Brazil, core lab, theoretical performance (patients managed by 0 h/3 h protocol), All patients followed up for 30 days; events adjudicated
  • Multicentre
  • Prospective cohort with retrospective analysis
  • 16 sites in Brazil
  • Core lab
  • Theoretical performance (patients managed by 0 h/3 h protocol)
  • All patients followed up for 30 days; events adjudicated

Performance

As reported in the abstract

Test or modelValueNPV for index AMIHEART score > 3
Rule-out74.4%100% (99.1-100)45.3%
Rule-in7.3%

Value

Rule-out74.4%
Rule-in7.3%

NPV for index AMI

Rule-out100% (99.1-100)
Rule-in— not stated in the abstract

HEART score > 3

Rule-out45.3%
Rule-in— not stated in the abstract

Further findings

OutcomeRule-outRule-in
Death or AMI at 30 daysRule-in value: patients adjudicated as AMI0 events52.4%
30-day AMI or CV death by troponin level (retrospective, n = 4.914) — 1.091 patients <5 ng/L; no CV deaths at 30 days
0
  • 30-day AMI or CV death by troponin level (retrospective, n = 4.914): < 5 ng/L 0%
  • 30-day AMI or CV death by troponin level (retrospective, n = 4.914): 5–14 ng/L 0.6%
  • 30-day AMI or CV death by troponin level (retrospective, n = 4.914): 14–42 ng/L 2.2%
  • 30-day AMI or CV death by troponin level (retrospective, n = 4.914): 42–90 ng/L 6.3%
  • 30-day AMI or CV death by troponin level (retrospective, n = 4.914): ≥ 90 ng/L 7.7%

Death or AMI at 30 days

No death or AMI in rule-out group of both 0/1 and 0/3 h algorithms

Risk discrimination in observation group (grey zone)

GRACE discriminated risk better than HEART score

Original publication