Arrhythmias & electrophysiology
Preceding Night Sleep Quality and Atrial Fibrillation Episodes in the I-STOP-AFIB Randomized Trial
Primary result · Self-reported AF episode next day, per worse sleep qualityResult — go to the resultOdds ratio 1.15 95% CI 1.10–1.20Authors' conclusion
Poor sleep was associated with an immediately heightened risk for self-reported AF episodes, and a dose-response relationship existed such that progressively worse sleep was associated with longer episodes of AF the next day.
Study context
- Population
- Patients with symptomatic paroxysmal atrial fibrillation (AF)15,755 days of data
- Participants
- 419 patients
- Comparison
- Worse vs better preceding-night sleep quality
- Primary endpoint
- Self-reported AF episode the next day
Primary result
As reported in the abstract
Self-reported AF episode next day, per worse sleep quality
Odds ratio
1.15
95% CI 1.10–1.20
P < 0.0001
Worse sleep quality
OR 1.15 (95% CI 1.10–1.20); P < 0.0001
Per worse sleep quality, as printed
Further findings
Mobile ECG-confirmed AF events · next day
| OR (95% CI) | P value | ||
|---|---|---|---|
| Worse sleep quality | 1.04 (0.95–1.13) | P = 0.43 | |
| 0.512Odds ratio (log scale) |
| Outcome | Difference (more minutes of AF) (95% CI) | P value | |
|---|---|---|---|
| Duration of self-reported AF episodes · next day | 16 (12–21) | P < 0.001 | |
| −100102030Difference, more minutes of AF (linear scale) |
- Mobile ECG-confirmed AF events: substantially fewer mobile ECG-confirmed events may have limited statistical power
Original publication
Preceding Night Sleep Quality and Atrial Fibrillation Episodes in the I-STOP-AFIB Randomized Trial. JACC Clin Electrophysiol. Published 1 November 2023. doi:10. 1016/ j. jacep. 2023. 09. 009
Composed by AI from the published abstract and checked against it. How Briefs are made →