Coronary disease & ACS

Predicting Late Gadolinium Enhancement of Acute Myocardial Infarction in Contrast-Free Cardiac Cine MRI Using Deep Generative Learning

Circ Cardiovasc ImagingPublished Diagnostic accuracy study

Authors' conclusion

CGE achieved superior image quality to LGE and accurate scar delineation in patients with acute MI of both internal and external data sets.

Study context

Population
Patients with acute myocardial infarction (MI) from 3 centres; plus normal subjects from a public cine cardiac magnetic resonance (CMR) data setacute MI, 3 centres
Participants
430 patients
Comparison
Cine-generated enhancement (CGE) from contrast-free cine CMR vs late gadolinium enhancement (LGE) CMR
Outcome
Image quality and MI quantification (scar size and transmurality) of CGE vs LGE
Methodological detailsmulticentre, internal and external testing, Training: 1525 pairs (289 patients), centre I; internal testing: 293 slices (52 patients); external testing: 40 patients (401 slices) from 2 other centres
  • Multicentre
  • Internal and external testing
  • Training: 1525 pairs (289 patients), centre I; internal testing: 293 slices (52 patients); external testing: 40 patients (401 slices) from 2 other centres

Performance

As reported in the abstract

Test or modelScar size Pearson correlation (internal/external)Scar size ICC (internal/external)Transmurality Pearson correlation (internal/external)Transmurality ICC (internal/external)Sensitivity for scar (all data sets)Specificity for scar (all data sets)
CGE0.79/0.800.79/0.770.76/0.640.76/0.6391.27%95.83%

CGE

Scar size Pearson correlation (internal/external)0.79/0.80
Scar size ICC (internal/external)0.79/0.77
Transmurality Pearson correlation (internal/external)0.76/0.64
Transmurality ICC (internal/external)0.76/0.63
Sensitivity for scar (all data sets)91.27%
Specificity for scar (all data sets)95.83%
Significant correlation between CGE and LGE for scar size and transmurality
P < 0.001

Further findings

Robustness in normal subjects (public cine CMR data set)

Realistic enhancement images without false positive subjects
  • 20 normal subjects

Image quality, CGE vs LGE

CGE image quality superior to LGE in internal and external data sets

Original publication

Predicting Late Gadolinium Enhancement of Acute Myocardial Infarction in Contrast-Free Cardiac Cine MRI Using Deep Generative Learning. Circ Cardiovasc Imaging. Published 10 September 2024. doi:10.1161/circimaging.124.016786

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.