Coronary disease & ACS

Predictors of target lesion failure after percutaneous coronary intervention with a drug-coated balloon for de novo lesions

EuroInterventionPublished Retrospective cohort study

Authors' conclusion

In de novo coronary artery lesions that received DCB treatment, factors associated with TLF were being on HD, the presence of a severely calcified lesion, and the absence of post-PCI medial dissection.

Study context

Population
Patients with de novo coronary artery lesions treated by percutaneous coronary intervention (PCI) with a drug-coated balloon (DCB) without a stent
Participants
328 lesions
Exposure
Target lesion failure (TLF) vs no TLF
  • TLFn = 31
Outcome
TLF (culprit lesion-related cardiac death, MI, target lesion revascularisation) and its associated factors
Follow-up
Median 460 days
Methodological detailsOptical coherence tomography (OCT) pre- and post-PCI
  • OCT pre- and post-PCI

Main finding

As reported in the abstract

Independent predictors of TLF (Cox multivariable analysis)

TLF

9.5%

31 of 31

Hazard ratio (95% CI)P value
HD vs No TLFhaemodialysis
2.26(1.00–5.11)
P = 0.049
Maximum calcium arc (per 90°)
1.34(1.05–1.72)
P = 0.02
Absence of post-PCI medial dissection on OCT vs No TLF
8.24(3.15–21.6)
P < 0.001

Observational data: associations, not effects.

Further findings

Characteristics, TLF vs no TLF

HD

Median maximum calcium arc TLF 215° · No TLF 104°

OCT medial dissection