Valvular & structural heart disease

Prospective validation of a prespecified algorithm for the management of conduction disturbances after transcatheter aortic valve replacement: The PROMOTE study

Heart RhythmPublished Prospective cohort study

Authors' conclusion

A prespecified strategy for the management of CDs in contemporary TAVR recipients was feasible and safe, with no increased mortality and an extremely low rate of sudden cardiac death in patients with CDs. However, PPM rates remained high

Study context

Population
Consecutive patients without prior pacemaker undergoing transcatheter aortic valve replacement (TAVR)
Participants
2,110 patients
Exposure
Prespecified CD management algorithm by group
Outcome
Permanent pacemaker (PPM) and mortality (overall, sudden cardiac death)
Follow-up
30 days
Methodological detailsmulticentre, consecutive patients, prespecified management algorithm
  • Multicentre
  • Consecutive patients
  • Prespecified management algorithm

Main finding

As reported in the abstract

PPM, all-cause mortality and SCD at 30 days

PPM

P < 0.001

All-cause mortality

P = 0.45

SCD

P = 0.99

Permanent pacemaker (PPM) overall at 30 days
329 (15.6%)

Observational data: associations, not effects.

Further findings

PPM by procedural CD type · 30 days

New-onset LBBB
17.4%
High-degree AV block/complete heart block
57.2%

Original publication

Prospective validation of a prespecified algorithm for the management of conduction disturbances after transcatheter aortic valve replacement: The PROMOTE study. Heart Rhythm. Published 16 December 2024. doi:10.1016/j.hrthm.2024.12.019

Summarised from the published abstract; every number is checked against it