Arrhythmias & electrophysiologyRandomised controlled trial

Pulmonary vein isolation durability in a randomized trial comparing fluoroscopy-only vs. electroanatomic mapping strategies for pulmonary vein isolation with balloon-in-basket pulsed-field ablation

EuropacePublished

  • Randomised controlled trial
  • prospective
  • single-centre

Authors' conclusion

A standardized balloon-in-basket PFA workflow for PVI achieved high PVI durability. EAM guidance did not confer additional procedural or durability benefit over fluoroscopy-only guidance.

Study context

Population
Consecutive patients with paroxysmal or persistent atrial fibrillation (AF) undergoing de novo pulmonary vein isolation (PVI) with a balloon-in-basket pulsed field ablation (PFA) catheter86 remapped
Participants
96 patients
Comparison
Fluoroscopy-only vs Fluoroscopy plus electroanatomic mapping (EAM)
Primary endpoint
Dual: proportion of PVs and of patients with all PVs durably isolated at invasive remapping
Follow-up
>30 days after index procedure

Primary result

As reported in the abstract

PVI durability (all patients) · median 41 days

Per-vein durability

341/350 (97.4%)

Per-patient durability

79/86 (91.9%)

Secondary outcomes

Procedural characteristics (all patients)

Fluoroscopy time, minutes
3.4 [2.4-4.6]
Number of applications
15 [13-16]
Chronic remapping parameters comparable between guidance strategies

Safety

Major adverse events within 30 days of index or remapping procedures

No major adverse events occurred