Arrhythmias & electrophysiology

Pulmonary vein isolation using pulsed field ablation vs. high-power short-duration radiofrequency ablation in paroxysmal atrial fibrillation: efficacy, safety, and long-term follow-up (PRIORI study)

EuropacePublished Retrospective cohort study

Authors' conclusion

Both PFA and HPSD-RF were highly efficient and effective in achieving PVI in paroxysmal AF patients. The arrhythmia-free survival is comparable. The PV reconnection rate was not different.

Study context

Population
Consecutive patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein isolation (PVI), real-world setting
Participants
410 patients
Exposure
PFA-PVI vs HPSD-RF PVI
  • Pulsed field ablation (PFA)n = 201
  • HPSD-RFn = 209reference
Outcome
Single-procedure freedom from any atrial tachyarrhythmia (Kaplan-Meier estimate)
Follow-up
1 year
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Freedom from any atrial tachyarrhythmia (Kaplan-Meier estimate)

Log-rank P = 0.160

Observational data: associations, not effects.

Further findings

Procedure time

P < 0.001

Fluoroscopy time

P < 0.01

Dose area product

P < 0.01

PV reconnection rate at repeat ablation (56 procedures)

P = 0.372

Safety

Overall complications

P = 0.158

OutcomePFAHPSD-RFP value
Fatal stroke1 eventsNot reported in the abstractHPSD-RF: not reported in the abstract

Original publication

Pulmonary vein isolation using pulsed field ablation vs. high-power short-duration radiofrequency ablation in paroxysmal atrial fibrillation: efficacy, safety, and long-term follow-up (PRIORI study). Europace. Published 12 July 2024. doi:10.1093/europace/euae194

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.