Arrhythmias & electrophysiologyCohort study

Pulsed field ablation with a pentaspline catheter and concomitant left atrial appendage closure for long-standing persistent atrial fibrillation: Comparison with a radiofrequency cohort

Heart RhythmPublished

  • observational, multicenter, propensity-matched study
  • consecutive patients
  • 1:1 matching based on age, CHA2DS2-VASc score, HAS-BLED score, and left atrial appendage occlusion (LAAO) device
  • follow-up censored at 12 months

Authors' conclusion

Extensive PFA, including LAA electrical isolation, combined with LAAO was feasible and safe, resulting in shorter procedures, fewer overall PDLs compared with RF but similar rate of PDL >3 mm.

Study context

Population
Patients with drug-refractory, long-standing persistent atrial fibrillation (AF) undergoing combined ablation (pulmonary veins, posterior wall, and LAA electrical isolation) plus LAAOPulsed field ablation (PFA) 45 · RF 45
Participants
90 consecutive patients
Exposure
extensive PFA combined with LAAO, compared with radiofrequency ablation plus LAAO
  • PFAn = 45
  • RFn = 45

Main finding

As reported in the abstract

Procedural time

P = 0.042

Observational data: associations, not effects.

Further findings

Overall peri-device leak (PDL) · lower with PFA

P = 0.048

Clinically relevant leaks >3 mm · infrequent and comparable

P = 0.494

Arrhythmic recurrences · 12 months · numerically lower with PFA; log-rank P = 0.093

P = 0.069

Acute LAAO success

Acute LAAO success in both groups
100%

Baseline characteristics

Baseline characteristics were balanced after matching

Predictors of recurrence (Cox regression)

AF duration >18 months predicted recurrence, hazard ratio
3.27, 95% confidence interval 1.15-9.32; P = 0.027
  • only AF duration >18 months predicted recurrence

Safety

OutcomePFARF
Complications (pericardial effusion) · similar complication rates1 events1 events
Stroke and major bleeding
StrokeNo strokesNot reported in the abstract
Major bleedingNo major bleedingNot reported in the abstract
Non-cardioembolic strokeNot reported in the abstract1
Major bleeding eventsNot reported in the abstract2

Original publication

Pulsed field ablation with a pentaspline catheter and concomitant left atrial appendage closure for long-standing persistent atrial fibrillation: Comparison with a radiofrequency cohort. Heart Rhythm. Published 17 April 2026. doi:10.1016/j.hrthm.2026.04.018

Summarised from the published abstract; every number is checked against it