Quantitative CT Lead Localization Reveals Proximal Left Bundle Targeting Facilitates Superior Physiologic Pacing

Heart RhythmPublished

  • proof-of-concept anatomic study
  • consecutive patients
  • observer-independent computed tomography workflow (CARA workflow)
  • prespecified rule

Authors' conclusion

In this proof-of-concept anatomic study, a 2-measurement rule classified CSP lead position objectively. Near-native paced activation requires proximal targeting (LH ≤ 25 mm), which neither the procedural label nor the ECG can identify; quantitative imaging is required.

Study context

Population
Consecutive patients undergoing conduction system pacing (CSP) with interpretable computed tomography anatomyof 186 consecutive patients undergoing CSP, with interpretable computed tomography anatomy, primary analysis set n = 46 · proximal 68 · distal 70 · left ventricular septal pacing 7
Participants
145 patients
Comparison
proximal vs distal CSP lead position
  • proximaln = 24
  • distaln = 22reference
Outcome
|Δ frontal axis| ≤ 15° and |Δ QRS duration| ≤ 15 ms (composite end point)

Main finding

As reported in the abstract

Each group vs distalOdds ratio (95% CI)P value
proximal
4.14(1.23–13.96)
P = 0.021
proximal
adjusted odds ratio 5.35; P = 0.013

Further findings

Positional information of procedural label

physician-labeled left bundle branch pacing leads that were proximal
48%
proximal overall
49%

Receiver operating characteristic-optimal LH cut point

LH cut point
24.9 mm
  • independently reproduced the prespecified 25-mm threshold

Position classification from surface ECG

classification area under the curve
0.48

Original publication

Quantitative CT Lead Localization Reveals Proximal Left Bundle Targeting Facilitates Superior Physiologic Pacing. Heart Rhythm. Published 20 September 2026. doi:10.1016/j.hrthm.2026.09.012

Summarised from the published abstract; every number is checked against it