Arrhythmias & electrophysiologyCohort study

Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR)

EuropacePublished

  • Multicentre registry study
  • 18 European centres

Authors' conclusion

In this complex population with refractory VA, ablation using the lattice-tip catheter appears feasible and relatively safe.

Study context

Population
Patients undergoing ventricular arrhythmia (VA) ablation with a lattice-tip catheter (AFFERA system), European centresVentricular tachycardia (VT) 99, premature ventricular complexes (PVCs) 23, ventricular fibrillation (VF) 4
Participants
126 patients

Main finding

As reported in the abstract

Absence of recurrence · mean follow-up 5.6 ± 3.7 months

Absence of recurrence, PVC

78%

Absence of recurrence, VT

70%

Absence of recurrence, VF

100%

Observational data: associations, not effects.

Safety

Acute complications

Major acute complications
7 (6%)
Minor acute complications
18 (14%)
Thrombo-embolic event
2
Major bleeding
2
VF induction
1
Tamponade due to epicardial access
1
Cardiogenic shock due to prolonged VT mapping
1

Events within first month post-procedure

Deaths (multi-organ failure 2, sepsis 1)
3
Worsening HF
2
MI
1
Sepsis
1
Major gastro-intestinal bleeding
1

Original publication

Safety and efficacy of a lattice-tip catheter for ventricular arrhythmia ablation: the AFFERA Ventricular Arrhythmia Ablation Registry (AVAAR). Europace. Published 2 July 2025. doi:10.1093/europace/euaf139

Summarised from the published abstract; every number is checked against it