Arrhythmias & electrophysiologyCohort study

Safety and efficacy of same-day discharge for premature ventricular complex ablations

EuropacePublished

  • Retrospective cohort study
  • single-centre

Authors' conclusion

Same-day discharge for CA of PVCs is feasible and could lower healthcare resource utilization without compromising outcomes in this unique population.

Study context

Population
Patients undergoing elective catheter ablation of premature ventricular complexes (PVCs), Ascension St Vincent Hospital, 2018–2019of 188 VA ablations
Participants
98 patients
Exposure
Same-day discharge vs non-same-day discharge after PVC ablation
  • SDDn = 55
Outcome
Procedural success (primary efficacy); complications and death (primary safety)
Follow-up
30 days (safety)

Main finding

As reported in the abstract

Acute procedural success

P = 0.68

Observational data: associations, not effects.

Further findings

OutcomeSDDnon-SDD
Complications and death (primary safety outcome) · 30 days0 events2.3%

Baseline differences

Non-SDD more likely on chronic anticoagulation
P = 0.03
Non-SDD more likely to have LV ablation
P = 0.04
Non-SDD more likely to have retrograde access
P = 0.03
Non-SDD more likely to receive heparin during procedure
P = 0.01

Original publication

Safety and efficacy of same-day discharge for premature ventricular complex ablations. Europace. Published 1 August 2024. doi:10.1093/europace/euae205