Arrhythmias & electrophysiology

Simulation of peri-mitral ablation lines using photon-counting computed tomography-based mapping of atrial wall thickness and epicardial adipose tissue

Heart RhythmPublished prospective imaging study with simulated ablation lines

Authors' conclusion

PCCT/3D-segmentation as a tool to visualize MT and EAT is very helpful to determine the most favorable line for catheter ablation of peri-mitral flutter. In a weighted score incorporating MT, EAT, and line length, AS and MII lines showed promising profiles for the creation of durable linear lesions.

Study context

Population
Patients undergoing photon-counting computed tomography (photon-counting computer tomography (PCCT)) of the left atriumpatients prospectively included, 990 simulated lines, 115,763 data points
Participants
198 patients
Exposure
Patterns of myocardial thickness (MT), epicardial adipose tissue (EAT), and length of commonly used left atrium (LA) lines
Outcome
Line length

Main finding

As reported in the abstract

  • Line length was shortest in MII, longest in anteromedial (AM)

Observational data: associations, not effects.

Further findings

MT

Anteroseptal (AS) showed the lowest average MT values
MT interpatient variability was greatest along the MIS

EAT

EAT distributed inhomogenously at the anterior wall, thicker medially and especially laterally; highest EAT levels along the anterolateral line (AL) line

Weighted score (MT, EAT, line length)

AS and MII lines demonstrated the most favorable profiles for catheter ablation

Original publication

Simulation of peri-mitral ablation lines using photon-counting computed tomography-based mapping of atrial wall thickness and epicardial adipose tissue. Heart Rhythm. Published 8 January 2026. doi:10.1016/j.hrthm.2026.01.001

Summarised from the published abstract; every number is checked against it