Arrhythmias & electrophysiology

Standardized Spark-Pattern Cut-Mode Electrosurgical Bailout Workflow for Difficult Left Bundle Branch Area Pacing Lead Advancement: Procedural and Follow-Up Outcomes From a 15-Patient Case Series

Circ Arrhythm ElectrophysiolPublished Case Series

Authors' conclusion

A standardized spark-pattern cut-mode bailout workflow provides a reproducible framework for difficult left bundle branch area pacing lead deployment. Progression markers should be distinguished from procedural success, and follow-up surveillance remains essential. Larger studies with longer follow-up and dedicated lead-integrity testing are required before general adoption.

Study context

Population
Patients undergoing standardized spark-pattern cut-mode electrosurgical bailout after conventional mechanical left bundle branch area pacing lead advancement failed
Participants
15 consecutive patients
Methodological detailsretrospective, consecutive patients
  • Retrospective
  • Consecutive patients

Main finding

As reported in the abstract

Procedural success of left bundle branch area pacing lead deployment

Spark-pattern cut-mode electrosurgical bailout

15/15

events

Observational data: associations, not effects.

Further findings

OutcomeValues
Progression markersSpark-pattern cut-mode electrosurgical bailout V1 terminal rightward progression 14/15 · jump 14/15 · split/discrete components 12/15

Spark-pattern cut-mode assistance activation

Target-site advancement attempts
50
Final target sites with activation
15
Cycles per patient
1.5±0.6
  • Conventional advancement failed in all included patients

Follow-up

Mean follow-up
400±170 days

Safety

OutcomeValues
Spark-associated premature ventricular complexesSpark-pattern cut-mode electrosurgical bailout 15/15 events

Spark-associated premature ventricular complexes

Isolated and self-limited; no nonsustained ventricular tachycardia, sustained ventricular tachycardia, polymorphic ventricular tachycardia/ventricular fibrillation, defibrillation, or hemodynamic instability during the standardized workflow

Lead and structural complications during follow-up · Mean follow-up 400±170 days

No clinically documented lead malfunction, dislodgement, microdislodgement, loss requiring revision, septal perforation, ventricular septal defect, pericardial effusion, or reintervention

Original publication

Standardized Spark-Pattern Cut-Mode Electrosurgical Bailout Workflow for Difficult Left Bundle Branch Area Pacing Lead Advancement: Procedural and Follow-Up Outcomes From a 15-Patient Case Series. Circ Arrhythm Electrophysiol. Published 7 October 2026. doi:10.1161/circep.126.015435

Summarised from the published abstract; every number is checked against it

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.