Valvular & structural heart diseaseCohort study

Stroke Risk After Transcatheter Aortic Valve Replacement (TAVR)

JACC AdvPublished

  • Registry analysis (Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry)
  • inverse probability of treatment weighting
  • weighted time-to-event models
  • CommonSpirit Health hospitals

Authors' conclusion

In this registry of patients receiving TAVR, valve type did not predict stroke at 1 year. The predominant drivers of stroke were clinical variables: age, STS risk, and a history of stroke.

Study context

Population
Patients who underwent TAVR across CommonSpirit Health hospitals from January 2021 to February 2023patients who underwent TAVR during the study period · balloon-expandable valve 5,445 · self-expanding valves (SEV) 1,218
Participants
6,663 patients
Exposure
association between valve type and the risk of stroke within 1 year after contemporary TAVR
  • balloon-expandable valven = 5,445
  • SEVn = 1,218
Outcome
Stroke-free survival
Follow-up
1 year

Main finding

As reported in the abstract

Adjusted hazard ratio

1.54

95% CI 0.79–2.68

P = 0.294

valve type
adjusted HR 1.54 (95% CI 0.79–2.68); P = 0.294

Observational data: associations, not effects.

Further findings

Female sex (baseline) · more females received a SEV

P < 0.001

Outcomeballoon-expandable valveSEVP value
STS risk score (baseline) · higher in the SEV groupmean 4.0 ± 3.5mean 4.5 ± 3.8P < 0.001

Stroke · within the study period

patients who experienced stroke
87 (1.3%)

Predictors of stroke

Age, lower body mass index, prior stroke, STS risk, and alternative access were associated with stroke

Original publication

Stroke Risk After TAVR. JACC Adv. Published 9 April 2026. doi:10.1016/j.jacadv.2026.102727

Summarised from the published abstract; every number is checked against it