Valvular & structural heart diseaseCohort study

Temporal Trends in Transcatheter Tricuspid Valve Interventions After FDA Approval in the United States

JACC AdvPublished

  • retrospective cohort study

Authors' conclusion

There is increased adoption of both T-TEER and TTVR in early commercial experience with clinical characteristics of treated patients similar to those enrolled in pivotal trials. In-hospital outcomes were overall favorable supporting the generalizability of the pivotal trial findings to contemporary practice.

Study context

Population
Patients who underwent Transcatheter Tricuspid Edge-to-edge Repair (T-TEER) or Transcatheter Tricuspid Valve Replacement (TTVR) in the Vizient Clinical Data Base between October 2024 and December 2025procedures · T-TEER procedures (180 implanting hospitals) 2,143 · TTVR procedures (113 implanting hospitals) 1,301
Participants
2,143 vs 1,301
Exposure
T-TEER vs TTVR
  • T-TEERn = 2,143
  • TTVRn = 1,301

Main finding

As reported in the abstract

Median annualized hospital volume

T-TEER

6.4

median · IQR 2.4–13.6

TTVR

6.4

median · IQR 3.2–11.2

Observational data: associations, not effects.

Further findings

OutcomeT-TEERTTVR
Overall monthly volumes · October 2024 to December 2025128 in October 2024 to 156 in December 202560 in October 2024 to 111 in December 2025
  • Overall monthly volumes: T-TEER P for trend = 0.004
  • Overall monthly volumes: TTVR P for trend <0.001

Proportion of TTVR among all TTVI

increased over time
from 31.9% to 41.6%
  • P for trend = 0.006

Baseline patient comorbidities

similar to pivotal trial populations

Safety

In-hospital mortality

Major bleeding

OutcomeT-TEERTTVR
New pacemaker implantationNot reported in the abstract11.3%

Original publication

Temporal Trends in Transcatheter Tricuspid Valve Interventions After FDA Approval in the United States. JACC Adv. Published 23 September 2026. doi:10.1016/j.jacadv.2026.103266

Summarised from the published abstract; every number is checked against it