Coronary disease & ACSSecondary analysis
The effect of zalunfiban on high sensitivity cardiac troponin and the association with clinical outcomes in patients with STEMI
- prespecified analysis
- core laboratory measurements
Authors' conclusion
Among patients with STEMI, more elevated concentrations of hs-cTnT are associated with worse measures of reperfusion and higher-risk for short-term death or heart failure. A single dose of zalunfiban at first medical contact reduced MI size.
Study context
- Population
- Patients with ST-segment elevation myocardial infarction (STEMI) treated with zalunfiban or placebo who had core laboratory hs-cTnT measurements
- Comparison
- zalunfiban compared to placebo; association of hs-cTnT concentrations with reperfusion measures and clinical outcomes
Primary result
As reported in the abstract
Resolution of ST deviation and Q wave development by hs-cTnT at presentation · presentation
More elevated hs-cTnT associated with less resolution of ST deviation
P = .006
More elevated hs-cTnT associated with more frequent Q wave development
P < .001
Further findings
| Outcome | OR | P value |
|---|---|---|
| Clinical outcomes by hs-cTnT at 24 hours · 30 days — per log unit increase in hs-cTnT at 24 hours · all-cause death · multivariable analyses | 1.83 | P = 0.03 |
| Clinical outcomes by hs-cTnT at 24 hours · 30 days — per log unit increase in hs-cTnT at 24 hours · cardiovascular death · multivariable analyses | 1.83 | P = 0.03 |
| Clinical outcomes by hs-cTnT at 24 hours · 30 days — per log unit increase in hs-cTnT at 24 hours · heart failure · multivariable analyses | 2.74 | P < 0.001 |
- Clinical outcomes by hs-cTnT at 24 hours — Higher hs-cTnT at 24 hours associated with composite of death and heart failure
- P < .001
Angiographic thrombus grade and epicardial and myocardial perfusion by hs-cTnT at presentation
- More elevated hs-cTnT associated with higher thrombus grade and worse epicardial and myocardial perfusion
- all P < .05
hs-cTnT and hs-cTnT determined Myocardial Infarction (MI) size · 24 hours
- zalunfiban had lower hs-cTnT compared to placebo
- P = 0.04
- Across multiples ≥ 10 to ≥ 1,000 times elevation, zalunfiban resulted in smaller hs-cTnT determined MI size
Original publication