Arrhythmias & electrophysiology

The “No-cut technique” for lead preparation in transvenous lead extraction

Heart RhythmPublished Observational cohort study

Authors' conclusion

NCT reported a higher rate of complete lead extraction, a lower rate of lead fragmentation, and better laboratory time without increased complications.

Study context

Population
Consecutive patients undergoing transvenous lead extraction (TLE) with the stepwise approach445 leads
Participants
205 patients
Exposure
No-cut technique vs conventional approach in TLE
  • NCTn = 111
Outcome
Complete procedural success
Methodological details2 tertiary centres, consecutive patients
  • 2 tertiary centres
  • Consecutive patients

Main finding

As reported in the abstract

P = 0.017

Observational data: associations, not effects.

Further findings

Clinical success

P = 0.501

Lead fragmentation

P = 0.027

Fluoroscopy use and laboratory time

Lower fluoroscopy use with NCT
P < 0.001
Shorter laboratory time with NCT
P < 0.001

1-year survival (overall)

Overall 1-year survival 98%
P = 0.627

Safety

Major complications 5 (2%), no deaths
P = 0.520

Original publication

The “No-cut technique” for lead preparation in transvenous lead extraction. Heart Rhythm. Published 12 December 2025. doi:10.1016/j.hrthm.2025.12.013

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.