Valvular & structural heart disease

Transcatheter aortic valve replacement outcomes in patients with low-flow very low-gradient aortic stenosis

Eur Heart J Cardiovasc ImagingPublished Retrospective cohort study

Main findingResult — go to the resultAdjusted hazard ratio 2.42 CI 1.29–4.55

Authors' conclusion

Low-flow very LG severe AS represents a distinct population with significant comorbidities and worse outcomes.

Study context

Population
Patients with low-flow severe aortic stenosis (AS), 2019–2021
Participants
662 patients
Exposure
Very low-gradient (LG) vs LG vs high-gradient (HG) low-flow severe AS
  • Very LGn = 130
  • LGn = 339
  • HGn = 193
Outcome
Composite of:
  • All-cause mortality
  • HF rehospitalization
Follow-up
Median 12 months
Methodological detailssingle-centre
  • Single-centre

Main finding

As reported in the abstract

Adjusted hazard ratio

2.42

CI 1.29–4.55

Very LG
adjusted HR 2.42 (CI 1.29–4.55)
Graded increase in risk of composite endpoint in lower mean pressure gradient (MPG) strata
P < 0.001

Observational data: associations, not effects.

Further findings

LVEF

OutcomeAdjusted HR (CI)
Composite endpoint, TAVRvs conservative management, by gradientVery LG: no risk reduction0.69 (0.35–1.34)
  • LVEF: P < 0.001

LVEF

Very LG had higher prevalence of comorbid conditions

Composite endpoint, transcatheter aortic valve replacement (TAVR) vs conservative management, by gradient

LG and HG had decreased risk of composite endpoint after TAVR vs conservative management

Original publication

Transcatheter aortic valve replacement outcomes in patients with low-flow very low-gradient aortic stenosis. Eur Heart J Cardiovasc Imaging. Published 29 September 2023. doi:10.1093/ehjci/jead243

Composed by AI from the published abstract and checked against it. How Briefs are made →