Valvular & structural heart diseaseCohort study

Transcatheter or Surgical Replacement for Failed Bioprosthetic Aortic Valves

JAMA CardiolPublished

  • Retrospective cohort study
  • population-based
  • propensity-score matched

Authors' conclusion

Compared with redo SAVR, ViV-TAVR was associated with a lower incidence of periprocedural complications and a similar incidence of all-cause mortality through 2 years' follow-up. However, ViV-TAVR was associated with higher rates of late mortality and heart failure hospitalization.

Study context

Population
Patients with failed bioprosthetic surgical aortic valve replacement (SAVR) undergoing ViV-TAVR or redo SAVR in California, New York and New Jersey, 2015–2020
Participants
1,771 patients · 375 matched pairs
Exposure
ViV-TAVR vs redo SAVR
Outcome
All-cause mortality
Follow-up
5 years

Main finding

As reported in the abstract

ViV-TAVR vs Redo SAVRHazard ratio (95% CI)
landmark analysis, up to 2 years
1.03(0.59–1.78)
landmark analysis, after 2 years
2.97(1.18–7.47)

Observational data: associations, not effects.

Secondary outcomes

OutcomeHR (95% CI)
HF hospitalization · after 2 years · landmark analysis3.81 (1.57–9.22)

Stroke, reoperation, major bleeding, infective endocarditis · 5 years

No differences in 5-year incidence

Periprocedural mortality and stroke

Similar between propensity-matched groups

Safety

Periprocedural major bleeding

P = 0.05

Periprocedural acute kidney failure

P < 0.001

Periprocedural new pacemaker implantation

P < 0.001

Original publication

Transcatheter or Surgical Replacement for Failed Bioprosthetic Aortic Valves. JAMA Cardiol. Published 1 July 2024. doi:10.1001/jamacardio.2024.1049

Summarised from the published abstract; every number is checked against it