Arrhythmias & electrophysiologyCohort study

Transseptal puncture and catheter ablation of atrial fibrillation in patients with atrial septal occluder devices: procedural techniques and outcomes

EuropacePublished

  • Retrospective case series
  • single-centre
  • consecutive patients

Authors' conclusion

TSP and AF ablation can be performed safely and effectively in patients with ASO devices.

Study context

Population
Patients with an atrial septal occluder device undergoing atrial fibrillation (AF) ablationof 1550 with atrial septal occluder (ASO) implantation
Participants
28 patients
Exposure
Transseptal puncture (TSP) through native septum vs through ASO device
  • Native septumn = 17
  • Device puncturen = 11
Outcome
Successful transseptal access (procedural outcomes)

Main finding

As reported in the abstract

Successful transseptal access

Transseptal access achieved

27 of 28 patients (96.4%)

Observational data: associations, not effects.

Further findings

Balloon dilation

Frequently required in device puncture cases

Pulmonary vein isolation and adjunctive ablation

Successfully completed in all patients

Safety

Major complications; residual interatrial shunts

No major complications
Small residual interatrial shunts immediately after the procedure resolved spontaneously during follow-up

Original publication

Transseptal puncture and catheter ablation of atrial fibrillation in patients with atrial septal occluder devices: procedural techniques and outcomes. Europace. Published 7 April 2026. doi:10.1093/europace/euag071

Summarised from the published abstract; every number is checked against it