Valvular & structural heart diseaseCohort study

Tricuspid Valve Transcatheter Edge-to-Edge Repair in Patients With Cardiac Implantable Electronic Devices

JACC Cardiovasc IntervPublished

  • Retrospective cohort study
  • multicentre
  • propensity-score matched

Authors' conclusion

T-TEER is safe and effective in selected patients with transvalvular CIED leads. Effective TR reduction remains prognostically relevant, even in this high-risk real-world population.

Study context

Population
Patients with severe tricuspid regurgitation (TR) undergoing T-TEER at 26 centres (2016–2024)
Participants
3,025 patients · 385 matched pairs
Exposure
T-TEER in patients with vs without transvalvular CIED leads
  • CIEDn = 851
Outcome
Composite of:
  • All-cause mortality
  • HF hospitalization
Follow-up
2 years

Main finding

2-year HF hospitalization-free survival

Hazard ratio

1.31

95% CI 0.99–1.74

P = 0.063

By group

CIED vs No CIED
HR 1.31 (95% CI 0.99–1.74); P = 0.063

As reported in the abstract

Observational data: associations, not effects.

Further findings

OutcomeOR (95% CI)P value
Residual TR >2+0.98 (0.70–1.38)P = 0.915

Residual TR (CIED) · discharge and follow-up (median 269 days; Q1-Q3: 63-423 days)

TR ≤1+ at discharge
39.9%
TR ≤2+ at discharge
79.8%
TR ≤1+ at follow-up
29.3%
TR ≤2+ at follow-up
69.1%

Survival by residual TR ≤2+

Residual TR ≤2+ conferred significantly better survival irrespective of CIED presence
P < 0.001

Safety

CIED function and lead revision

CIED function remained stable; no lead revision required

Original publication

Tricuspid Valve Transcatheter Edge-to-Edge Repair in Patients With Cardiac Implantable Electronic Devices. JACC Cardiovasc Interv. Published 25 October 2025. doi:10.1016/j.jcin.2025.09.033

Summarised from the published abstract; every number is checked against it