Coronary disease & ACSRandomised controlled trial

Ultra-Thin Sirolimus-Eluting Versus Everolimus-Eluting Stents in Diabetic Multivessel Coronary Artery Disease Patients

J Am Coll CardiolPublished

  • Randomised controlled trial
  • investigator-initiated
  • prospective
  • open-label
  • multicentre
  • 2 × 2 factorial
  • non-inferiority
  • Patients also randomised to ticagrelor or prasugrel

Authors' conclusion

In patients with diabetes and multivessel disease undergoing percutaneous coronary intervention, ultra-thin biodegradable polymer SES was noninferior to durable polymer EES at 1 year follow-up.

Study context

Population
Patients with diabetes and multivessel disease undergoing PCI
Participants
1,800 patients
Comparison
Ultra-thin BP-SES vs DP-EES
Primary endpoint
Target lesion failure:
  • Cardiac death
  • Target vessel MI
  • Ischemia-driven target lesion revascularization
Follow-up
1 year

Primary result

Target lesion failure

Risk difference

−0.83 percentage points

PNI = 0.005

Events by treatment group

As reported in the abstract

Further findings

Components of target lesion failure · 1 year

Cardiac death, BP-SES vs DP-EES (no significant difference)
3.6% vs 3.4%
Target vessel MI, BP-SES vs DP-EES (no significant difference)
6.61% vs 7.54%
Ischemia-driven target lesion revascularization, BP-SES vs DP-EES (no significant difference)
0.8% vs 1.0%

Nonfatal MI · 1 year

Nonfatal MI, BP-SES vs DP-EES (similar)
4.7% vs 6.4%

Safety

Stent thrombosis · 1 year

Stent thrombosis, BP-SES vs DP-EES (similar)
1.0 % vs 0.7%

Original publication

Ultra-Thin Sirolimus-Eluting Versus Everolimus-Eluting Stents in Diabetic Multivessel Coronary Artery Disease Patients. J Am Coll Cardiol. Published 1 July 2026. doi:10.1016/j.jacc.2026.05.025

Summarised from the published abstract; every number is checked against it