Valvular & structural heart diseaseCohort study

UNICORN During Transcatheter Aortic Valve Replacement in Native and Bioprosthetic Aortic Valves

JACC Cardiovasc IntervPublished

  • Multicentre registry study
  • 9 sites
  • consecutive patients

Authors' conclusion

UNICORN during TAVR was successful in preventing coronary obstruction. Intraprocedural hypotension requiring vasopressor support was frequent.

Study context

Population
Patients undergoing UNICORN transcatheter aortic valve replacement (TAVR) in native, surgical or transcatheter aortic valves, March 2024 to May 20258 native, 30 surgical, 15 TAVR valves
Participants
53 patients
Outcome
Primary success: UNICORN TAVR without periprocedural coronary obstruction, reintervention or death

Main finding

As reported in the abstract

Primary success (UNICORN TAVR without periprocedural coronary obstruction, reintervention or death)

Primary success

51 patients (96%)

Observational data: associations, not effects.

Further findings

Coronary obstruction requiring rescue PCI

Coronary obstruction with rescue PCI
2 (4%)

Safety

Overall 30-day safety

Overall 30-day safety
46 patients (87%)
Stroke
3 (6%)
Life-threatening bleeding
2 (4%)
Major vascular complications
2 (4%)
Deaths, valve-related reinterventions, stage 3–4 AKI
0

Intraprocedural hypotension

Intraprocedural hypotension
12 (23%)

Original publication

UNICORN During Transcatheter Aortic Valve Replacement in Native and Bioprosthetic Aortic Valves. JACC Cardiovasc Interv. Published 22 June 2026. doi:10.1016/j.jcin.2026.04.030

Summarised from the published abstract; every number is checked against it