Cardiometabolic & kidneyCohort study

Venous Excess Ultrasound Score (VExUS) Point-of-Care Ultrasound Tool to Detect Changes in Volume Status

JACC AdvPublished

  • prospective observational study

Authors' conclusion

Fluid removal with HD was associated with changes in the VExUS score, highlighting the utility of VExUS to capture dynamic shifts in intravascular volume in patients with end-stage renal disease.

Study context

Population
Inpatients with end-stage renal disease undergoing hemodialysis (HD)92 paired ultrasound exams
Participants
Forty-six inpatients
Exposure
pre-HD and post-HD VExUS scores
Outcome
Change in composite VExUS score (scale 0 to 4)
Follow-up
Before and after hemodialysis

Main finding

As reported in the abstract

Median score decrease

1.5

95% CI 1–2

P < 0.001

Observational data: associations, not effects.

Further findings

Linear relationship between volume removed and change in VExUS score

No significant linear relationship
  • univariate linear regression

Volume of fluid removed with HD

median volume of fluid removed
2,000 mL (IQR: 985-2,500 mL)

Original publication

VExUS Point-of-Care Ultrasound Tool to Detect Changes in Volume Status. JACC Adv. Published 29 January 2026. doi:10.1016/j.jacadv.2025.102538