Valvular & structural heart diseaseCohort study

30-Day and 1-Year Outcomes From the Optimize PRO Transcatheter Aortic Valve Replacement (TAVR) Evolut FX Addendum Study

JACC Cardiovasc IntervPublished

  • Prospective nonrandomised study
  • postmarket
  • multicentre
  • single-group
  • Median follow-up 371 days (Q1-Q3: 352-388 days)

Authors' conclusion

Implantation of the Evolut FX device with a refined COT was associated with low PPI rates and no severe AR at 1 year. Postprocedural CT demonstrated consistent commissural and coronary alignment.

Study context

Population
Patients with severe AS undergoing TAVR
Participants
151 patients
Outcome
All-cause mortality or all stroke
Follow-up
30 days and 1 year

Main finding

As reported in the abstract

All-cause mortality or all stroke at 30 days

2.7% (95% CI: 1.0%-6.9%)

All-cause mortality or all stroke at 1 year

7.5% (95% CI: 4.2%-13.1%)

Observational data: associations, not effects.

Further findings

Commissural alignment

By marker positioning on fluoroscopy
91.5% (107 of 117)
By computed tomography (CT)
86.9% (113 of 130)
  • good agreement

Compliance with the refined cusp overlap technique (COT)

Compliance with the refined COT
86.0%

Length of stay

Median length of stay
1 day

Coronary alignment on CT

No severe coronary misalignment
>92%

Safety

New permanent pacemaker implantation (PPI)

New PPI at 30 days
6.7% (95% CI: 3.7%-12.1%)
New PPI at 1 year
8.8% (95% CI: 5.2%-14.6%)

Aortic regurgitation (AR) · 1 year

Moderate AR
1
Severe AR
0