Arrhythmias & electrophysiology

Acute oesophageal safety and long-term follow-up of ablation index (AI)-guided high-power short-duration with 50 W for atrial fibrillation ablation

EuropacePublished Retrospective cohort study

Main finding · Endoscopically detected thermal oesophageal lesions (EDEL)Result — go to the resultOdds ratio 4.799 CI 1.427–16.138

Authors' conclusion

High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions.

Study context

Population
Patients undergoing first atrial fibrillation (AF) ablation with AI-guided HPSD (50 W) using ThermoCool SmartTouch SF catheter
Participants
795 patients
Exposure
AI 400/300 vs AI 450/350 HPSD AF ablation
  • AI 400/300n = 211
  • AI 450/350n = 584reference
Outcome
Endoscopically detected thermal oesophageal lesions (EDEL)
Methodological detailsconsecutive patients
  • Consecutive patients

Main finding

As reported in the abstract

Odds ratio

4.799

CI 1.427–16.138

P = 0.011

By group

AI 450/350
OR 4.799 (CI 1.427–16.138); P = 0.011

Observational data: associations, not effects.

Further findings

Single-procedure success, AI 400/300 vs AI 450/350 · 12 months; long-term after mean 25 ± 7 months

12-month success comparable between target AI groups: 76% vs. 76%
P = 0.892
Long-term success comparable between target AI groups: 68% vs. 71%
log-rank P = 0.452

Single-procedure success, paroxysmal vs persistent AF (subgroup) · 12 months; end of follow-up

12 months: paroxysmal vs persistent AF 80% vs. 72%
P = 0.010
End of follow-up: paroxysmal vs persistent AF 76% vs. 65%
log-rank P = 0.001

Redo procedures and pulmonary vein (PV) reconnection · during follow-up

Patients undergoing redo procedure
103 (16%)
Comparable PV reconnection among groups

Multivariate predictors of AF recurrence

Age, left atrium (LA) size, persistent AF and extra-PV ablation targets

Original publication