Valvular & structural heart diseaseCohort study

Bioprosthetic Valve Failure After Transcatheter Aortic Valve Replacement

Circ Cardiovasc IntervPublished

  • international, multicenter registry
  • consecutive patients
  • 13 centers
  • competing-risk approach
  • Bioprosthetic valve failure (BVF) as a time-dependent covariate

Authors' conclusion

BVF is a clinically relevant event associated with adverse long-term outcomes. These findings support the implementation of tailored surveillance and preventive strategies to mitigate BVF-related risk.

Study context

Population
Consecutive patients undergoing transcatheter aortic valve replacement
Participants
7,501 patients
Exposure
BVF as a time-dependent covariate and clinical outcomes
  • BVFn = 380
Outcome
BVF according to Valve Academic Research Consortium-3 criteria
Follow-up
Median 4 (interquartile range, 2-5) years

Main finding

As reported in the abstract

BVF occurred

380 (5.1%)

Cumulative incidence at 1 year

1.4%

Cumulative incidence at 5 years

4.6%

Cumulative incidence at 10 years

8.3%

Observational data: associations, not effects.

Further findings

Independent predictors of BVF

younger age, smoking, balloon-expandable valve, prosthesis size <26 mm, valve-in-valve procedure, mean gradient at discharge ≥15 mm Hg, moderate or severe aortic regurgitation at discharge, and early hemodynamic valve deterioration

Clinical outcomes associated with BVF

All-cause mortality, adjusted hazard ratio
1.72 [95% CI, 1.47-2.01]; P <0.001
Cardiovascular mortality, adjusted hazard ratio
3.23 [95% CI, 2.73-3.82]; P <0.001
Stroke, adjusted hazard ratio
2.08 [95% CI, 1.02-4.23]; P =0.043
Heart failure hospitalization, adjusted hazard ratio
1.43 [95% CI, 1.03-1.98]; P =0.032
  • increased risk with BVF
  • Consistent findings were observed in different sensitivity analyses.

Original publication

Bioprosthetic Valve Failure After Transcatheter Aortic Valve Replacement. Circ Cardiovasc Interv. Published 24 August 2026. doi:10.1161/circinterventions.126.016892

Summarised from the published abstract; every number is checked against it