Arrhythmias & electrophysiology

Bronchial Safety After Pulsed Field Ablation for Paroxysmal Atrial Fibrillation

Circ Arrhythm ElectrophysiolPublished Prospective observational study

Authors' conclusion

Pulmonary vein isolation using PFA for paroxysmal atrial fibrillation does not cause thermal lesions in the bronchial system.

Study context

Population
Patients undergoing pulmonary vein isolation with pulsed field ablation (PFA) for paroxysmal AF2 series of 30
Participants
30 vs 30
Exposure
Straight-tip vs J-tip guide wire during PFA
  • Straight-tip guide wiren = 30
  • J-tip guide wiren = 30
Outcome
Bronchial effects on bronchoscopy
Follow-up
1 day after procedure
Methodological details2 series
  • 2 series

Main finding

As reported in the abstract

Bronchoscopy findings · 1 day

Straight-tip guide wire

40%

12 of 30

Observational data: associations, not effects.

Further findings

Acute PV isolation

All pulmonary veins acutely isolated

Safety

Clinical course and hemoglobin · 30 days

No chest discomfort, coughing or hemoptysis
Hemoglobin levels remained clinically stable
All patients asymptomatic at 30-day follow-up

Original publication

Bronchial Safety After Pulsed Field Ablation for Paroxysmal Atrial Fibrillation. Circ Arrhythm Electrophysiol. Published 13 March 2023. doi:10.1161/circep.122.011547

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.