Arrhythmias & electrophysiology
Bronchial Safety After Pulsed Field Ablation for Paroxysmal Atrial Fibrillation
Authors' conclusion
Pulmonary vein isolation using PFA for paroxysmal atrial fibrillation does not cause thermal lesions in the bronchial system.
Study context
- Population
- Patients undergoing pulmonary vein isolation with pulsed field ablation (PFA) for paroxysmal AF2 series of 30
- Participants
- 30 vs 30
- Exposure
- Straight-tip vs J-tip guide wire during PFA
- Straight-tip guide wiren = 30
- J-tip guide wiren = 30
- Outcome
- Bronchial effects on bronchoscopy
- Follow-up
- 1 day after procedure
Methodological details2 series
- 2 series
Main finding
As reported in the abstract
Bronchoscopy findings · 1 day
Straight-tip guide wire
40%
12 of 30
Observational data: associations, not effects.
Further findings
Acute PV isolation
- All pulmonary veins acutely isolated
Safety
Clinical course and hemoglobin · 30 days
- No chest discomfort, coughing or hemoptysis
- Hemoglobin levels remained clinically stable
- All patients asymptomatic at 30-day follow-up